Heating or plumbing emergency? We’ve got you covered!

Heating, Cooling, Plumbing & Indoor Air Quality Services in Old Town & Gold Coast, IL

Old Town & Gold Coast Service Overview

  • Historic Residential Properties: Old Town and the Gold Coast include pre-1900 rowhomes, mansions, historic residences, and older properties where the mechanical system needs to be considered alongside the building itself.
  • High-Rise & Modern Residences: Newer high-rise residences closer to Lake Shore Drive and Oak Street can have very different heating, cooling, plumbing, and comfort requirements.
  • Full-Service Mechanical Trades: Deljo Heating, Cooling & Plumbing provides heating, cooling, plumbing, and indoor air quality service throughout Old Town, the Gold Coast, and the 60610 ZIP code.

In Old Town and the Gold Coast, the mechanical system is only part of the job. A pre-1900 rowhome along Astor Street may have original plaster, detailed woodwork, and hydronic heat that deserves a careful approach, while a modern high-rise closer to Lake Shore Drive presents a completely different set of comfort needs. Here, getting the work right often means improving the system without losing sight of the property around it.

Deljo Heating, Cooling & Plumbing provides heating, cooling, plumbing, and indoor air quality service throughout Old Town, the Gold Coast, and the 60610 ZIP code. Call 773-829-4295 or contact us online to schedule service.

technicians in front of truck

Home Services Built Around Historic & Modern Chicago Properties

Old Town and the Gold Coast bring together historic rowhomes, mansions, multi-level residences, and modern high-rise condos. The right heating, cooling, plumbing, or indoor air quality approach depends on the property, the existing system, and how much of the finished space needs to remain undisturbed.

Solving HVAC, Plumbing & Indoor Air Quality Issues in Old Town & Gold Coast

Problem: Older residences can have historic finishes, plaster, woodwork, and hydronic systems that require careful service, while high-rise residences can have individual systems and building conditions that create a completely different set of requirements.

Solution: Deljo evaluates the actual property and mechanical system before determining whether repair, maintenance, replacement, airflow improvements, humidity control, or another service is appropriate.

Boiler, Steam & Heating Service in Old Town & Gold Coast

Steam and hot-water boilers remain an important part of heating service in the neighborhood’s older residences. Mansions and pre-war rowhomes around Astor Street and the Old Town Triangle can still rely on hydronic systems that have served the property for decades.

Elsewhere in 60610, furnaces, heat pumps, and newer high-efficiency equipment are part of the mix. In high-rise residences closer to the lakefront, the heating setup can be completely different from what we find in a rowhome or mansion farther west. When an Old Town or Gold Coast heating system needs attention, the work may involve:

A heating call near the Charnley-Persky House may involve a very different system from one closer to Oak Street or Lake Shore Drive. We focus on how the property is actually heated before deciding whether repair, maintenance, or replacement is the right path.

“Sam was very knowledgeable and easy to work with. He was patient and capable of explaining the situation with ease.”

Eric P

Stay warm all winter long! Call Deljo at 773-829-4295 to schedule heating service in Old Town or the Gold Coast.

AC Repair, Ductless Cooling & Discreet System Upgrades

Cooling can be one of the trickier parts of working in older Old Town and Gold Coast residences. Conventional ductwork is not always practical where homeowners want to preserve plaster, millwork, or other finished surfaces. Ductless and concealed systems can offer another way to add or improve cooling without making the installation more disruptive than it needs to be.

Repairmen works on a home's air conditioner unit outdoors.

The high-rise side of the neighborhood brings a different set of conditions. Units closer to Lake Shore Drive can have their own cooling systems, different exposures, and very different load demands from the older homes farther west. For cooling that fits the property instead of fighting against it, Deljo offers:

The Old Town Art Fair fills Wisconsin and Lincoln avenues each June, while the Gold Coast Art Fair brings more summer activity nearby. Inside the home, we are focused on keeping the space comfortable with a system that works naturally with the building.

“Had the A/C Checked out and some other things to the roof unit. Mr Mora was quick and efficient at checking things out and doing what needed to be done. Yep, it’s cold.”

Kenneth B

Beat the summer heat with reliable AC service! Call Deljo at 773-829-4295 to schedule cooling service in Old Town or the Gold Coast.

Indoor Air Quality, Humidity & Smart Comfort Controls

Comfort problems in Old Town and the Gold Coast are not always tied to failed equipment. In larger multi-level homes along Astor Street or North State Parkway, one floor can feel very different from another. Original plaster, natural woodwork, and older interiors can also make humidity control more noticeable, especially during Chicago winters.

High-rise condos bring their own concerns. Residents closer to Lake Shore Drive or Oak Street may be more focused on thermostat control, filtration, and getting better performance from an individual system without making unnecessary changes to the rest of the unit. For homes where comfort depends on more than temperature alone, Deljo can help with:

The goal is practical: better airflow, more balanced humidity, cleaner air, and controls that make the system easier to live with every day.

Plumbing Service for Old Town Homes & Gold Coast Residences

Plumbing work here can be as much about access and care as the repair itself. In an older rowhome or mansion, a pipe repair, fixture replacement, or bathroom update may need to be completed around finished surfaces the homeowner wants protected. In a high-rise residence, access and shared building infrastructure can become part of the job.

pipe repair

Around Astor Street, Oak Street, Rush Street, and the Old Town Triangle, plumbing needs range from everyday repairs to larger upgrades in kitchens and bathrooms. When plumbing problems show up, Deljo can take care of:

Whether we are tracing a leak, replacing a fixture, or working around a finished interior, the goal is to solve the problem cleanly and keep unnecessary disruption to a minimum.

“Greg was professional, prompt, attentive. Actively answered questions and offered advice. Would use this service again.”

Jeremy G

Need plumbing help in Old Town or the Gold Coast? Call Deljo at 773-829-4295 to schedule service.

Local Service From Astor Street to the Old Town Triangle

The Gold Coast stretches from North Avenue to Oak Street and from Lake Shore Drive west to Clark Street, bringing mansions, rowhomes, and high-rise residences into a compact part of Chicago. Astor Street remains one of the area’s defining residential corridors, while Oak Street and Rush Street add a much busier commercial and entertainment side.

Old Town shifts the feel again. The Old Town Triangle preserves much of the neighborhood’s 19th-century character, while Second City anchors an active entertainment district nearby. North State Parkway adds another tree-lined residential corridor with Victorian and Edwardian architecture.

That mix matters on service calls. One address may involve a boiler serving a multi-level historic home, while another may involve newer forced-air equipment or condo systems in a high-rise only a few blocks away.

Comfort Service That Respects the Property

Homeowners in Old Town and the Gold Coast are often looking for two things at once: dependable comfort and work that respects the property itself. That can mean preserving a boiler that still makes sense, improving cooling without tearing into finished spaces, or handling a plumbing repair with as little disruption as possible.

Deljo Heating, Cooling & Plumbing provides heating, cooling, plumbing, and indoor air quality service throughout Old Town, the Gold Coast, Astor Street, the Old Town Triangle, North State Parkway, Oak Street, Rush Street, and the surrounding 60610 ZIP code. Call 773-829-4295 or contact us online to schedule service.

Old Town & Gold Coast Homeowners FAQ

What heating services does Deljo provide in Old Town and the Gold Coast?

A: Deljo provides heating installation, heating repair, heating maintenance, furnace service and replacement, heat pump service, and boiler service.

Does Deljo service boiler and steam heating systems?

A: Yes. Boiler service is included among Deljo’s heating services, and steam and hot-water boilers remain an important part of heating service in many older residences in the area.

Does Deljo provide AC repair and installation in Old Town and the Gold Coast?

A: Yes. Deljo provides AC repair, AC installation, AC maintenance, heat pump service, and ductless AC service.

Can ductless cooling be useful in older Old Town or Gold Coast homes?

A: Ductless and concealed systems can offer another way to add or improve cooling where conventional ductwork is not practical or where homeowners want to preserve plaster, millwork, or other finished surfaces.

What indoor air quality services does Deljo provide?

A: Deljo can help with air duct cleaning, Aeroseal, indoor air quality inspection and testing, air filtration, purifying ionizers, air purifiers, whole-home humidifiers, whole-home dehumidifiers, thermostats, and AC coil and condenser cleaning.

What plumbing services are available in Old Town and the Gold Coast?

A: Deljo provides emergency plumbing services, drain cleaning, water heaters, whole-home water filters, pipe repair, frozen pipe service, flood control, sump pumps, plumbing fixtures, repiping, sewer lines, and showers and bathtubs.

Page Updated on September 18, 2026

Recent Jobs and Reviews in Chicago, IL

Chicago, IL at a glance

Deljo Heating, Cooling & Plumbing has completed 20 jobs in Chicago, IL in October 2026.

The most recent job was on October 19, 2026.

Deljo Heating, Cooling & Plumbing has completed 11,972 jobs in Chicago, IL in the last 12 months.

Job Locations and Reviews

Performed seasonal maintenance on two furnaces, including replacement of 16x25x1 and 20x25x1 air filters and servicing of both humidifiers with new #35 water panel evaporators. Verified thermostat operation, confirming the heating cycle engaged and responded properly to the set-point call for heat. Reviewed local municipal water source data (surface water supply) to inform humidifier scale and mineral buildup maintenance.
Performed seasonal maintenance on two furnaces, including replacement of 16x25x1 and 20x25x1 air filters and servicing of both humidifiers with new #35 water panel evaporators. Verified thermostat operation, confirming the heating cycle engaged and responded properly to the set-point call for heat. Reviewed local municipal water source data (surface water supply) to inform humidifier scale and mineral buildup maintenance.
Izzy G.
Izzy G. Checked in
Performed seasonal maintenance on two furnaces, including replacement of 16x25x1 and 20x25x1 air filters and servicing of both humidifiers with new #35 water panel evaporators. Verified thermostat operation, confirming the heating cycle engaged and responded properly to the set-point call for heat. Reviewed local municipal water source data (surface water supply) to inform humidifier scale and mineral buildup maintenance.
Chicago, IL 60610
Returned to complete the callback for a bathroom pedestal sink and reinstalled the missing drain stopper assembly that was omitted during the prior home inspection visit. Inspected the supply lines, shutoff valves, and drain arm behind the pedestal and found no leaks, corrosion, or visible damage. Sink is fully functional with the stopper operating properly.
Returned to complete the callback for a bathroom pedestal sink and reinstalled the missing drain stopper assembly that was omitted during the prior home inspection visit. Inspected the supply lines, shutoff valves, and drain arm behind the pedestal and found no leaks, corrosion, or visible damage. Sink is fully functional with the stopper operating properly.
Jorge D.
Jorge D. Checked in
Returned to complete the callback for a bathroom pedestal sink and reinstalled the missing drain stopper assembly that was omitted during the prior home inspection visit. Inspected the supply lines, shutoff valves, and drain arm behind the pedestal and found no leaks, corrosion, or visible damage. Sink is fully functional with the stopper operating properly.
Chicago, IL 60645
Performed scheduled maintenance on the basement boiler, inspecting the flue connection, gas piping and shutoff valve, circulator pump, and associated piping for leaks, corrosion, and proper operation. Removed and inspected the pilot assembly, thermocouple, and burner tube, noting heat staining and discoloration on the burner, and serviced the components to restore reliable ignition and flame performance. Equipment was found intact with no active leaks or frost, and the system was returned to normal operation.
Performed scheduled maintenance on the basement boiler, inspecting the flue connection, gas piping and shutoff valve, circulator pump, and associated piping for leaks, corrosion, and proper operation. Removed and inspected the pilot assembly, thermocouple, and burner tube, noting heat staining and discoloration on the burner, and serviced the components to restore reliable ignition and flame performance. Equipment was found intact with no active leaks or frost, and the system was returned to normal operation.
Charlie B.
Charlie B. Checked in
Performed scheduled maintenance on the basement boiler, inspecting the flue connection, gas piping and shutoff valve, circulator pump, and associated piping for leaks, corrosion, and proper operation. Removed and inspected the pilot assembly, thermocouple, and burner tube, noting heat staining and discoloration on the burner, and serviced the components to restore reliable ignition and flame performance. Equipment was found intact with no active leaks or frost, and the system was returned to normal operation.
Chicago, IL 60640
Responded to a dead, unresponsive Carrier Infinity thermostat following a power surge; the HVAC system was not operating despite restored power. Inspected the furnace cabinet and low-voltage control wiring, tested for control voltage with a handheld meter, and checked the furnace and thermostat connections for surge-related damage. No visible rust, frost, or physical damage was found at the equipment.
Responded to a dead, unresponsive Carrier Infinity thermostat following a power surge; the HVAC system was not operating despite restored power. Inspected the furnace cabinet and low-voltage control wiring, tested for control voltage with a handheld meter, and checked the furnace and thermostat connections for surge-related damage. No visible rust, frost, or physical damage was found at the equipment.
Drew W.
Drew W. Checked in
Responded to a dead, unresponsive Carrier Infinity thermostat following a power surge; the HVAC system was not operating despite restored power. Inspected the furnace cabinet and low-voltage control wiring, tested for control voltage with a handheld meter, and checked the furnace and thermostat connections for surge-related damage. No visible rust, frost, or physical damage was found at the equipment.
Chicago, IL 60610
Responded to a no-heat call on a boiler system over 20 years old, performed a CO safety check with ambient reading of 0 ppm, and inspected the mechanical room piping, valves, and ductwork. Noted corrosion and mineral deposits at the floor drain/pipe stub area and torn duct insulation, and recommended further evaluation of the aging boiler system and repair of the damaged insulation.
Responded to a no-heat call on a boiler system over 20 years old, performed a CO safety check with ambient reading of 0 ppm, and inspected the mechanical room piping, valves, and ductwork. Noted corrosion and mineral deposits at the floor drain/pipe stub area and torn duct insulation, and recommended further evaluation of the aging boiler system and repair of the damaged insulation.
Drew W.
Drew W. Checked in
Responded to a no-heat call on a boiler system over 20 years old, performed a CO safety check with ambient reading of 0 ppm, and inspected the mechanical room piping, valves, and ductwork. Noted corrosion and mineral deposits at the floor drain/pipe stub area and torn duct insulation, and recommended further evaluation of the aging boiler system and repair of the damaged insulation.
Chicago, IL 60637
Responded to a no-heat call on a 5-year-old furnace controlled by an ecobee smart thermostat, which showed normal operation at a 69°F reading with 55% humidity and no visible anomalies. Inspected the 24x24x1 pleated return air filter and found it clean with no restriction, tears, or damage, ruling out restricted airflow as the cause. Per customer notes, no maintenance was performed during this visit.
Responded to a no-heat call on a 5-year-old furnace controlled by an ecobee smart thermostat, which showed normal operation at a 69°F reading with 55% humidity and no visible anomalies. Inspected the 24x24x1 pleated return air filter and found it clean with no restriction, tears, or damage, ruling out restricted airflow as the cause. Per customer notes, no maintenance was performed during this visit.
Drew W.
Drew W. Checked in
Responded to a no-heat call on a 5-year-old furnace controlled by an ecobee smart thermostat, which showed normal operation at a 69°F reading with 55% humidity and no visible anomalies. Inspected the 24x24x1 pleated return air filter and found it clean with no restriction, tears, or damage, ruling out restricted airflow as the cause. Per customer notes, no maintenance was performed during this visit.
Chicago, IL 60622
Responded to a no-heat call where the thermostat would not switch to heat mode; inspected and programmed the Honeywell Home digital thermostat and checked the furnace burner compartment, including the gas valve, burner assembly, and low-voltage wiring connections. Verified proper thermostat operation and call-for-heat response, restoring normal heating function.
Responded to a no-heat call where the thermostat would not switch to heat mode; inspected and programmed the Honeywell Home digital thermostat and checked the furnace burner compartment, including the gas valve, burner assembly, and low-voltage wiring connections. Verified proper thermostat operation and call-for-heat response, restoring normal heating function.
Izzy G.
Izzy G. Checked in
Responded to a no-heat call where the thermostat would not switch to heat mode; inspected and programmed the Honeywell Home digital thermostat and checked the furnace burner compartment, including the gas valve, burner assembly, and low-voltage wiring connections. Verified proper thermostat operation and call-for-heat response, restoring normal heating function.
Chicago, IL 60630
Responded to a no-heat call on a system under 10 years old. Verified the thermostat was calling for heat (set point 75°F, space at 63°F) and measured a supply register air temperature of approximately 56°F, confirming the system was not producing heat. Documented the findings and noted dust and lint buildup on the supply grille, which should be cleaned to support proper airflow.
Responded to a no-heat call on a system under 10 years old. Verified the thermostat was calling for heat (set point 75°F, space at 63°F) and measured a supply register air temperature of approximately 56°F, confirming the system was not producing heat. Documented the findings and noted dust and lint buildup on the supply grille, which should be cleaned to support proper airflow.
Drew W.
Drew W. Checked in
Responded to a no-heat call on a system under 10 years old. Verified the thermostat was calling for heat (set point 75°F, space at 63°F) and measured a supply register air temperature of approximately 56°F, confirming the system was not producing heat. Documented the findings and noted dust and lint buildup on the supply grille, which should be cleaned to support proper airflow.
Chicago, IL 60611
Responded to a no-heat call on a 10+ year-old furnace with a pilot light that would not ignite. Inspected the ecobee thermostat by removing the faceplate and checking the backplate wiring terminals (Rc, Rh, W1, C, Y1) for secure connections and damage, and confirmed the thermostat wiring was intact with no visible corrosion or loose conductors. Reinstalled the thermostat and verified the display and heat call were operating normally.
Responded to a no-heat call on a 10+ year-old furnace with a pilot light that would not ignite. Inspected the ecobee thermostat by removing the faceplate and checking the backplate wiring terminals (Rc, Rh, W1, C, Y1) for secure connections and damage, and confirmed the thermostat wiring was intact with no visible corrosion or loose conductors. Reinstalled the thermostat and verified the display and heat call were operating normally.
Izzy G.
Izzy G. Checked in
Responded to a no-heat call on a 10+ year-old furnace with a pilot light that would not ignite. Inspected the ecobee thermostat by removing the faceplate and checking the backplate wiring terminals (Rc, Rh, W1, C, Y1) for secure connections and damage, and confirmed the thermostat wiring was intact with no visible corrosion or loose conductors. Reinstalled the thermostat and verified the display and heat call were operating normally.
Chicago, IL 60647
Responded to a no-heat complaint on a furnace under 10 years old and inspected the control board, which cycled through idle ("idl") and "HE" status codes, with the board powered and 24VAC present, and found no visible damage, corrosion, or loose connections at the wiring harness. Verified the sequence of operation and ignition system function, and the unit was restored to normal heating operation.
Responded to a no-heat complaint on a furnace under 10 years old and inspected the control board, which cycled through idle ("idl") and "HE" status codes, with the board powered and 24VAC present, and found no visible damage, corrosion, or loose connections at the wiring harness. Verified the sequence of operation and ignition system function, and the unit was restored to normal heating operation.
Sam A.
Sam A. Checked in
Responded to a no-heat complaint on a furnace under 10 years old and inspected the control board, which cycled through idle ("idl") and "HE" status codes, with the board powered and 24VAC present, and found no visible damage, corrosion, or loose connections at the wiring harness. Verified the sequence of operation and ignition system function, and the unit was restored to normal heating operation.
Chicago, IL 60622
Diagnosed a no-heat call on a 10+ year old gas furnace showing a three-flash fault code for an open pressure switch with the inducer energized. Inspection of the burner compartment revealed significant corrosion on the burner/manifold mounting bracket and heavy rust throughout the cabinet floor pan, indicating chronic moisture exposure, likely from condensate or flue-related leakage. The corrosion and the open pressure switch condition point to a restricted or compromised venting/draft path; the unit is not operating safely and requires further repair or evaluation of the vent system and corroded components before it can be returned to service.
Diagnosed a no-heat call on a 10+ year old gas furnace showing a three-flash fault code for an open pressure switch with the inducer energized. Inspection of the burner compartment revealed significant corrosion on the burner/manifold mounting bracket and heavy rust throughout the cabinet floor pan, indicating chronic moisture exposure, likely from condensate or flue-related leakage. The corrosion and the open pressure switch condition point to a restricted or compromised venting/draft path; the unit is not operating safely and requires further repair or evaluation of the vent system and corroded components before it can be returned to service.
Sam A.
Sam A. Checked in
Diagnosed a no-heat call on a 10+ year old gas furnace showing a three-flash fault code for an open pressure switch with the inducer energized. Inspection of the burner compartment revealed significant corrosion on the burner/manifold mounting bracket and heavy rust throughout the cabinet floor pan, indicating chronic moisture exposure, likely from condensate or flue-related leakage. The corrosion and the open pressure switch condition point to a restricted or compromised venting/draft path; the unit is not operating safely and requires further repair or evaluation of the vent system and corroded components before it can be returned to service.
Chicago, IL 60622
Responded to a reported auxiliary heat malfunction on a 5-year-old heat pump system and inspected the outdoor equipment, including the electrical disconnect and conduit, junction boxes, and insulated refrigerant lines, finding no signs of frost, ice, or corrosion. Inspected the indoor air handler and found a heavily dust-loaded return air filter with a displaced filter pad, which restricts airflow and can affect auxiliary heat operation. Serviced the filter assembly and documented all findings with photos.
Responded to a reported auxiliary heat malfunction on a 5-year-old heat pump system and inspected the outdoor equipment, including the electrical disconnect and conduit, junction boxes, and insulated refrigerant lines, finding no signs of frost, ice, or corrosion. Inspected the indoor air handler and found a heavily dust-loaded return air filter with a displaced filter pad, which restricts airflow and can affect auxiliary heat operation. Serviced the filter assembly and documented all findings with photos.
Gerardo M.
Gerardo M. Checked in
Responded to a reported auxiliary heat malfunction on a 5-year-old heat pump system and inspected the outdoor equipment, including the electrical disconnect and conduit, junction boxes, and insulated refrigerant lines, finding no signs of frost, ice, or corrosion. Inspected the indoor air handler and found a heavily dust-loaded return air filter with a displaced filter pad, which restricts airflow and can affect auxiliary heat operation. Serviced the filter assembly and documented all findings with photos.
Chicago, IL 60618
Responded to a no-heat call on a gas furnace in a 1-hour ignition lockout with pilot not igniting. Accessed the burner, gas valve, and control board compartments and inspected the ignition system, gas supply, flue connections, and low-voltage wiring, using test leads to diagnose the ignition circuit. Cleared the lockout condition and verified proper ignition and heating operation.
Responded to a no-heat call on a gas furnace in a 1-hour ignition lockout with pilot not igniting. Accessed the burner, gas valve, and control board compartments and inspected the ignition system, gas supply, flue connections, and low-voltage wiring, using test leads to diagnose the ignition circuit. Cleared the lockout condition and verified proper ignition and heating operation.
Sam A.
Sam A. Checked in
Responded to a no-heat call on a gas furnace in a 1-hour ignition lockout with pilot not igniting. Accessed the burner, gas valve, and control board compartments and inspected the ignition system, gas supply, flue connections, and low-voltage wiring, using test leads to diagnose the ignition circuit. Cleared the lockout condition and verified proper ignition and heating operation.
Chicago, IL 60651
Inspected the 15-year-old boiler for the reported startup noise during heat-up, including the gas control valve, burner assembly, wiring connections, and associated piping, circulator pumps, and expansion tank. Documented the unit's condition with photos, noting dust and grime buildup throughout the cabinet and equipment, and verified the system produces heat to the radiators with the noise subsiding once operating temperature is reached.
Inspected the 15-year-old boiler for the reported startup noise during heat-up, including the gas control valve, burner assembly, wiring connections, and associated piping, circulator pumps, and expansion tank. Documented the unit's condition with photos, noting dust and grime buildup throughout the cabinet and equipment, and verified the system produces heat to the radiators with the noise subsiding once operating temperature is reached.
Sam A.
Sam A. Checked in
Inspected the 15-year-old boiler for the reported startup noise during heat-up, including the gas control valve, burner assembly, wiring connections, and associated piping, circulator pumps, and expansion tank. Documented the unit's condition with photos, noting dust and grime buildup throughout the cabinet and equipment, and verified the system produces heat to the radiators with the noise subsiding once operating temperature is reached.
Chicago, IL 60646
Removed and replaced the existing furnace and evaporator coil with new matched equipment, completing the installation with a two-technician crew in one day. Verified system operation with a digital manometer (approximately 7.87 inWC pressure reading) and connected a digital manifold gauge to monitor R410A refrigerant pressures and temperatures during startup.
Removed and replaced the existing furnace and evaporator coil with new matched equipment, completing the installation with a two-technician crew in one day. Verified system operation with a digital manometer (approximately 7.87 inWC pressure reading) and connected a digital manifold gauge to monitor R410A refrigerant pressures and temperatures during startup.
Richard G.
Richard G. Checked in
Removed and replaced the existing furnace and evaporator coil with new matched equipment, completing the installation with a two-technician crew in one day. Verified system operation with a digital manometer (approximately 7.87 inWC pressure reading) and connected a digital manifold gauge to monitor R410A refrigerant pressures and temperatures during startup.
Chicago, IL 60625
Performed an on-site replacement estimate for an existing 1995 Rheem Criterion gas furnace (approximately 31 years old) in the basement utility area, inspecting the unit's condition, nameplate data, flue and ductwork connections, and gas piping. Took cabinet measurements to determine sizing and fit for a like-for-like replacement, and documented the installation with photos for proposal preparation.
Performed an on-site replacement estimate for an existing 1995 Rheem Criterion gas furnace (approximately 31 years old) in the basement utility area, inspecting the unit's condition, nameplate data, flue and ductwork connections, and gas piping. Took cabinet measurements to determine sizing and fit for a like-for-like replacement, and documented the installation with photos for proposal preparation.
Tyler B.
Tyler B. Checked in
Performed an on-site replacement estimate for an existing 1995 Rheem Criterion gas furnace (approximately 31 years old) in the basement utility area, inspecting the unit's condition, nameplate data, flue and ductwork connections, and gas piping. Took cabinet measurements to determine sizing and fit for a like-for-like replacement, and documented the installation with photos for proposal preparation.
Chicago, IL 60622
Performed scheduled maintenance on two furnaces and one second-floor humidifier, inspecting blower assemblies and noting dust accumulation on the squirrel-cage blower wheels, with no visible rust, cracking, or major damage. Replaced 20x20x1 filters and serviced the 16x25x4 media filter cabinet, with filter media not included. Reset maintenance reminders on the Infinity system and scheduled the next seasonal maintenance visit six months out.
Performed scheduled maintenance on two furnaces and one second-floor humidifier, inspecting blower assemblies and noting dust accumulation on the squirrel-cage blower wheels, with no visible rust, cracking, or major damage. Replaced 20x20x1 filters and serviced the 16x25x4 media filter cabinet, with filter media not included. Reset maintenance reminders on the Infinity system and scheduled the next seasonal maintenance visit six months out.
Sam A.
Sam A. Checked in
Performed scheduled maintenance on two furnaces and one second-floor humidifier, inspecting blower assemblies and noting dust accumulation on the squirrel-cage blower wheels, with no visible rust, cracking, or major damage. Replaced 20x20x1 filters and serviced the 16x25x4 media filter cabinet, with filter media not included. Reset maintenance reminders on the Infinity system and scheduled the next seasonal maintenance visit six months out.
Chicago, IL 60622
Performed a full-system replacement evaluation on a 2012 split-system air conditioner with a history of recurring refrigerant leaks and a suspected compromised line set. Inspected the outdoor condenser (noting corrosion at the fan motor hub) and measured the condenser and the American Standard furnace in the utility area to determine sizing, gas piping and PVC venting configuration, and clearances for a matched condenser, coil, and furnace replacement with new line set.
Performed a full-system replacement evaluation on a 2012 split-system air conditioner with a history of recurring refrigerant leaks and a suspected compromised line set. Inspected the outdoor condenser (noting corrosion at the fan motor hub) and measured the condenser and the American Standard furnace in the utility area to determine sizing, gas piping and PVC venting configuration, and clearances for a matched condenser, coil, and furnace replacement with new line set.
Tyler B.
Tyler B. Checked in
Performed a full-system replacement evaluation on a 2012 split-system air conditioner with a history of recurring refrigerant leaks and a suspected compromised line set. Inspected the outdoor condenser (noting corrosion at the fan motor hub) and measured the condenser and the American Standard furnace in the utility area to determine sizing, gas piping and PVC venting configuration, and clearances for a matched condenser, coil, and furnace replacement with new line set.
Chicago, IL 60646
Responded to a leaking Rheem 75-gallon tank-style water heater and inspected the unit, its supply and relief piping, and the adjacent mechanical equipment, including the well pump, pressure tank, and expansion tank. Photos showed rust staining and mineral deposits at the threaded joints and pressure tank near the pump and gauge, while the water heater exterior showed no visible rust or significant damage. Service work was completed to address the leak, and the equipment was left in operational condition.
Responded to a leaking Rheem 75-gallon tank-style water heater and inspected the unit, its supply and relief piping, and the adjacent mechanical equipment, including the well pump, pressure tank, and expansion tank. Photos showed rust staining and mineral deposits at the threaded joints and pressure tank near the pump and gauge, while the water heater exterior showed no visible rust or significant damage. Service work was completed to address the leak, and the equipment was left in operational condition.
Giovanni M.
Giovanni M. Checked in
Responded to a leaking Rheem 75-gallon tank-style water heater and inspected the unit, its supply and relief piping, and the adjacent mechanical equipment, including the well pump, pressure tank, and expansion tank. Photos showed rust staining and mineral deposits at the threaded joints and pressure tank near the pump and gauge, while the water heater exterior showed no visible rust or significant damage. Service work was completed to address the leak, and the equipment was left in operational condition.
Chicago, IL 60657
Responded to a customer complaint of odor from the supply vents on a 10+ year old Carrier air handler. Inspection revealed a heavily scaled evaporator pad in the whole-house humidifier, with mineral buildup and corrosion on the cabinet seams. The pad and frame were removed, rinsed, and cleaned of mineral deposits, then the humidifier was serviced and reinstalled. The system was operated through a heating cycle to confirm proper function and that the odor was eliminated.
Responded to a customer complaint of odor from the supply vents on a 10+ year old Carrier air handler. Inspection revealed a heavily scaled evaporator pad in the whole-house humidifier, with mineral buildup and corrosion on the cabinet seams. The pad and frame were removed, rinsed, and cleaned of mineral deposits, then the humidifier was serviced and reinstalled. The system was operated through a heating cycle to confirm proper function and that the odor was eliminated.
Izzy G.
Izzy G. Checked in
Responded to a customer complaint of odor from the supply vents on a 10+ year old Carrier air handler. Inspection revealed a heavily scaled evaporator pad in the whole-house humidifier, with mineral buildup and corrosion on the cabinet seams. The pad and frame were removed, rinsed, and cleaned of mineral deposits, then the humidifier was serviced and reinstalled. The system was operated through a heating cycle to confirm proper function and that the odor was eliminated.
Chicago, IL 60607

Client Testimonials

Read the opinions of our satisfied customers.

5 stars

This was my first time as a Deljo customer, and I was very pleased. My technician, Giovanni, was very thorough and diligent. He serviced my furnace and identified a faulty sensor that was causing the unit to shut itself down. Deljo ordered the part, and Giovanni replaced it a few days later. Overall, the team at Deljo was great. The dispatcher kept me informed about Giovanni’s arrival time, and the supervisor assisted Giovanni when he was diagnosing the problem with the furnace. I highly recommend Deljo.

Paul D. 10/15/2026

5 stars

I’ve used Deljo for over 10 years now and they always do a good job. Izzy was the technician for this visit and he did an excellent job with my winter maintenance on my multiple units in the household. He also addressed an issue while cleaning the furnace blower wheel. His communication was clear and concise with what he planned to do to address the issue quickly. He was confident and I had 0 concerns or questions. Great job Izzy!

Jeff S. 10/14/2026

5 stars

Paul was great! Arrived on time and completed maintenance on my humidifier, tankless water heater, and two furnaces. All work was performed under my Gold Star maintenance program, so all maintenance charges were covered. Paul did provide a few proposals for additional services on furnace & tankless water heater, but those were emailed to me for further consideration. Paul was friendly, knowledgeable, and answered all my questions.

Jack N. 10/12/2026

5 stars

Gabe did an excellent job with our annual service visit. He arrived in the early part of our service window, was friendly and knowledgeable, and got the work done in a very reasonable amount of time. I have great confidence in Deljo, and am a long-time customer.

Ruth C. 10/9/2026

5 stars

I’ve been using Deljo for 20 years for HVAC but now venture into enlisting their plumbing services. Bashar was very courteous, efficient & informative, and I’d definitely request him again for the next plumbing job. Great experience!

Christopher R. 10/2/2026

5 stars

Working with Deljo is always a good experience, and today’s appointment with Izzy was no different. He was able to come early which actually worked better with our schedules, but called me ahead of time to make sure that was okay. He was friendly and knowledgeable when he explained the work he had done during his visit and our options for fixes. He was also able to schedule a quote appointment for us while he was still here. We would highly recommend working with Izzy and the Deljo team!

Lauren H.  9/25/2026

5 stars

Drew performed the seasonal maintenance on my AC. It needed some repairs and updates and he was able to fix everything at the same appointment. He also noticed issues with the hot water heater and we were able to get ahead of that, as well.

Emily W. 9/11/2026

5 stars

I would leave six out of five stars if I could! My technician Jorge went above and beyond on his service. There was buildup in the rental property’s toilet from the previous tenant. One maintenance person did a surface level job of cleaning but did not fully remove the obstruction. Jorge went above and beyond and came to a solution and even explained the perpetual problems older toilet models can cause. Moving forward with this insight, I can perform my own upkeep the previous tenant did not. Thank you kindly!

Kayla K.  9/15/2026

5 stars

We just had our new boiler installed by Jonathan and Carlos. First rate work! They arrived on time, removed the old boiler, installed the new unit, and explained the features. Both guys were pleasant. Bring on the cold this winter! We are ready thanks to the team from Deljo.

Edward B.  6/26/2026

5 stars

Deljo’s heating and cooling team was awesome to work with. As a first-time homeowner, I really appreciated how clearly they explained everything and answered all my questions. From the quote to the install and follow-up, the service was top-notch. Highly recommend!

Lindsey A. Chicago, IL

5 stars

Matt did an amazing job. He serviced our home and our rental property. He gave us options to help our systems run more efficiently. He also told us about Deljo’s new plumbing inspection which was very affordable. He is great!

Jordan R. Chicago, IL

5 stars

We had a problem with our Humidifier and called Deljo. Jesus came out to help and was amazing. He was extremely knowledgeable, detail oriented, and super courteous. Amazing customer experience!

Jeff C. Chicago, IL

5 stars

Jordan and Jesus were extremely helpful and knowledgeable! We would 100% work with them and have them back. They were both very professional and efficiently fixed our heating system.

Emily L. Chicago, IL

5 stars

Shout out to Ernesto for coming out and servicing our furnace and air con. Deljo provides a great service and glad to trust them with our HVAC for our small business.